Title: Power Grid Correction Using Sensitivity Analysis
Authors: Aydonat, Meric
Advisor: Najm, Farid N.
Department: Electrical and Computer Engineering
Keywords: Sensitivity analysis
Linear programming
Power grid
Issue Date: 14-Dec-2010
Abstract: Power grid voltage integrity verification requires checking if all the voltage drops on the grid are less than a certain threshold that guarantees proper circuit operation. This thesis addresses the problem of correcting the grid when some voltage drops exceed this threshold by making minor modifications to the existing design. The method uses current constraints that capture the uncertainty about the underlying circuit behavior to find the maximum voltage drop on the grid, and then to estimate the voltage drop as a function of the metal widths on the grid. It formulates a nonlinear optimization problem and finds the required change in widths that reduces the maximum voltage drop on the grid below the threshold while keeping the total area cost at a minimum.
URI: http://hdl.handle.net/1807/25415
Appears in Collections:Master
The Edward S. Rogers Sr. Department of Electrical & Computer Engineering - Master theses

Files in This Item:

File Description SizeFormat
Aydonat_Meric_201011_MASc_thesis.pdf590.98 kBAdobe PDF